Window air leakage ratings describe airflow through a closed window under specified test conditions. Lower comparable values mean less leakage, but the number must stay with its unit, test pressure, product configuration and supporting record. It does not by itself predict drafts after installation.
For a U.S. residential window order, compare the documented assembly and the proposed installation together. A good glass specification cannot answer every question about operating seals or the joint between the frame and wall. Begin with our window selection and project buying hub if you are still choosing the overall window package.
This guide focuses on a practical buying decision: can two quoted leakage values be compared, and what needs to be written into the order before a deposit? It does not substitute a residential label for a commercial project specification or local approval.
1. What do window air leakage ratings measure?
Air leakage, often shortened to AL, is different from heat transfer through the window materials. Berkeley Lab explains that leakage is reported separately from U-factor and SHGC, and that laboratory ratings and measurements on installed windows serve different purposes. See its window rating guidance.
Write the full unit alongside the air infiltration rating. A value stated in cfm per square foot expresses airflow per unit of window area; a value per linear foot uses a different basis. The U.S. Department of Energy purchasing guide specifically warns that both reporting forms can appear. Matching the digits alone is not a valid comparison.
For each supplier, request the test pressure and the test or certification reference. If one quotation has a lower number but omits its conditions, mark the comparison as incomplete. Ask for the missing information before treating it as a performance upgrade.
A useful comparison row reads: product series, opening arrangement, stated leakage, unit, pressure, evidence reference and applicable size or configuration. Keep an unverified sales value separate from the documented value until the supplier provides the record.
A calculation example, not a product claim
Suppose a report gives 0.10 cfm/ft² for a 20 ft² specimen under its stated test conditions. Multiplication gives 2 cfm at those conditions. A second otherwise comparable result of 0.05 cfm/ft² gives 1 cfm for the same area. That is half the test airflow. It is not proof of half the heating bill, half the household leakage or half the drafts in a particular room.
These numbers are arithmetic examples, not George test results or recommended project limits. Do not use a specimen-area calculation to extrapolate a rating to a different size unless the supporting certification or test scope permits it.

2. Is the value a limit, an exact result or a missing field?
The U.S. ENERGY STAR Version 7 specification, Section 3.C and Table 5, sets an air leakage limit of ≤ 0.3 cfm/ft² for qualifying windows. It permits specified alternative certification labels as evidence. A displayed upper limit does not reveal the exact leakage measured below that limit. This is a voluntary program criterion, not a statement that every project or jurisdiction uses the same requirement.
| What the quotation shows | What you can conclude | What to request next |
|---|---|---|
| ≤ 0.3 cfm/ft² | A declared ceiling, with its evidence still to check | Applicable label or record and any detailed result needed for comparison |
| 0.05 with no unit or pressure | A number without enough context | Complete unit, conditions, method and product identification |
| Blank AL field | No leakage value established by that field | Separate applicable evidence; never enter zero on its behalf |
| Report for a fixed window | Evidence for the product scope stated in the report | Evidence covering the operable product actually quoted |
Read the actual certification route instead of rejecting a qualifying product merely because one optional-looking box is blank. Conversely, a logo on a brochure is not enough to identify which model or configuration it covers. Ask the supplier to connect the order line to the relevant record.
Remember to check: our NFRC vs ENERGY STAR window checklist explains the separate roles of product ratings and program qualification. Use that guide for label and climate-zone checks, then return to the leakage comparison for this order.
3. Does the evidence match your quoted window?
The best comparison sheet follows the window schedule. Give each opening a reference and record the proposed series, dimensions, fixed or operable parts, opening direction and hardware package. Ask the supplier to identify which record covers each line, including any stated limits or permitted variations.
For example, a wide assembly with a fixed center and two opening side panels needs a clear description. A result for an unrelated small fixed sample does not answer the buying question. Request an explanation of the documented scope rather than guessing that every item sharing a frame material has the same performance.
- Match the manufacturer and series names across quote, supporting record and final order.
- Identify the tested or rated configuration and the scope claimed for the proposed unit.
- Keep glass, sash, locking hardware and seal specifications with the relevant drawing revision.
- List unresolved items separately; do not silently copy a value into every schedule row.
- Ask for written confirmation when the supplier proposes a substitution.
Discuss weatherstripping, compression seals and replaceable operating parts while the order is still editable. Ask which parts are included, which maintenance instructions apply and how replacement parts are identified. A clear service route is more useful than an unsupported lifetime promise.

Have a preliminary window schedule? Share the project location, opening sizes and the two specifications you want to compare so the enquiry starts with the same scope.
4. Are casement, sliding and picture windows being compared fairly?
The Natural Resources Canada window-upgrading guide explains that fixed windows may be more airtight, while operable types provide ventilation or potential escape routes. That functional distinction does not establish the result for two specific products. Compare their documented values and conditions. This reference explains opening functions; it is not a Canadian approval claim for a U.S. order.
Start with what the room needs before choosing the lowest number. Picture windows are fixed; casement windows and sliding windows provide different opening arrangements. Ask the project designer to confirm ventilation, access and any applicable emergency escape requirements before removing an opening function from the schedule.
A fair shortlist can include more than one opening style. Where the room needs an operable unit, compare suitable operable options. Where a fixed view is appropriate, assess the fixed unit on its own requirements. Keep operating space, screen arrangement, cleaning access and hardware availability in the decision.
Do not award an entire contract to a frame material on the strength of one showroom sample. Ask for the model-specific evidence behind each proposed style. Then compare the complete supply scope, including handles, screens, trim, packaging and any site work included in the quotation.

5. Who is responsible for the frame to wall air seal?
The window unit and the rough opening are separate parts of the buying scope. Pacific Northwest National Laboratory guidance identifies the gap between the frame and rough opening as a leakage path and calls for air sealing before trim. It also says fibrous insulation alone should not be relied on to block airflow.
Before placing the order, ask who designs, supplies and installs the perimeter joint. Request the relevant window installation instructions and the proposed wall-interface detail. Have the project team reconcile the air seal with flashing, drainage, substrate conditions and the product instructions rather than treating any visible bead of sealant as a complete detail.
Put responsibility into the quotation. If windows are supplied only, identify the installation contractor and the documents they need before delivery. If installation is included, list preparation, perimeter materials, trim and completion checks. Make any exclusions visible while suppliers can still price the same work.
For an existing draft complaint, record where and when it occurs. A qualified assessment may distinguish leakage at an operating joint, the frame to wall connection or another part of the enclosure. Berkeley Lab discusses installed-window leakage measurement separately from laboratory testing. A factory rating alone cannot diagnose the house.

6. What other requirements must stay in the purchase brief?
Window air leakage ratings answer one performance question. Keep window U-factor, SHGC, structural requirements, water performance, safety glazing and any project-specific approvals in separate fields. Do not replace those checks with the word airtight.
The ENERGY STAR specification lists ASTM E283 in accordance with NFRC 400, or the stated NAFS route, for its air leakage testing. Its scope and certification criteria should be read as a package. Do not turn a test-method name on a supplier spreadsheet into a blanket approval for another market or building type.
Ask your designer or approving authority which requirements apply at the actual address. A U.S. residential program limit should not be exported into a Canadian, Australian or UK specification without checking that market’s current rules and the proposed product category.
Remember to check: if the project is in Florida, our Florida Product Approval and Miami-Dade NOA buying checklist covers the separate approval-record review. Passing a leakage criterion does not settle that review.
7. What should be agreed before the order is released?
Create a comparison record that the buyer, supplier and installer can all read. A short, traceable file is easier to use than a collection of screenshots with no link to the proposed order. Keep the source report or certification record, its relevant page and the quotation revision together.
| Decision field | Information to record |
|---|---|
| Project and opening | Address, room or opening reference, dimensions and opening function |
| Product identification | Manufacturer, series, drawing revision, glass and operating configuration |
| Leakage comparison | Value or limit, full unit, test pressure, method and supporting reference |
| Project acceptance | Required criteria and the party confirming the proposed product is suitable |
| Installation scope | Wall detail, perimeter air seal, installation instructions and responsible contractor |
| Commercial scope | Included parts, exclusions, delivery protection, inspection and service route |
If a lower leakage value changes the price, ask for two otherwise comparable options. Identify the exact specification difference and supporting evidence. Keep the base package, opening sizes and installation scope constant so the buyer can judge what the additional cost actually purchases.
At delivery, inspect visible damage, seals and hardware against the order and follow the supplied handling instructions. At handover, record operation and outstanding defects with the installer. Visual inspection is useful, but it is not a substitute for a specified performance test.

Send George your project location, window schedule, preferred opening styles, performance brief, current quotations and installation scope. Include the records you already have and highlight the questions still unresolved.
FAQs about window air leakage ratings
What is a good window air leakage rating?
Lower values indicate less leakage when the products, units and test conditions are comparable. U.S. ENERGY STAR Version 7 sets a window limit of ≤ 0.3 cfm/ft², but your project may specify a different target. Confirm the applicable requirement and supporting product evidence.
Does a label showing ≤ 0.3 mean the window leaks exactly 0.3?
No. It states an upper limit rather than an exact measured result. Request the applicable record and any detailed result needed to compare products below that limit.
Does a low U-factor mean a window will not feel drafty?
No. U-factor and air leakage describe different performance characteristics. Also review operating seals and the installed frame to wall connection; a glass or thermal rating alone does not establish those conditions.
Are casement windows always more airtight than sliding windows?
No. An opening-style name alone does not establish the ranking of two specific products. Compare documented results for the actual models under comparable conditions and retain the opening functions the project needs.
Can good window air leakage ratings guarantee a draft free installation?
No. Laboratory product performance does not establish the quality of the installed perimeter joint or diagnose other leakage paths. Coordinate installation instructions, the wall detail and any specified field checks with the responsible project team.
What should I ask a window supplier before paying a deposit?
Ask for the exact product and opening configuration, leakage value or limit with its unit and conditions, supporting record, relevant project requirements, installation responsibilities and complete quotation inclusions. Resolve missing information in writing before releasing the order.