WaterMark vs WELS comes down to two different checks: WaterMark addresses plumbing product conformity and fitness for purpose; WELS addresses water efficiency registration and labelling. For many Australian bathroom fittings, buyers need to check both. A water saving star rating does not replace a required plumbing certification. The Australian Government explains this distinction in its WaterMark and WELS consumer protection guidance.
Before paying a deposit, identify the exact fixture, its intended use, the registered model and the installation location. Then ask your installer to review the documents against the project. This guide sets out seven checks for homeowners, importers and project buyers choosing basin mixer taps, showers and toilets.
Scope: Australian supply and installation are separate questions. Product exclusions, personal imports and state or territory rules can change the answer. Official requirements linked below were checked on 14 October 2026.
Coordinating these checks with the rest of the room? Use the George bathroom fixture buying hub to organise fixture selection, installation interfaces, delivery milestones and the quotation package.
WaterMark vs WELS: what does each one prove?
Use the two schemes as different columns in your approval schedule. Neither column should contain only a supplier’s “Australian compliant” statement. Ask for identifiers that can be checked independently.
| Buyer question | WaterMark | WELS |
|---|---|---|
| What is its purpose? | Plumbing product conformity, health, safety and fitness for purpose | Water efficiency registration, ratings and labelling |
| What should I request? | WaterMark licence number and the relevant product listing | WELS registration number, registered model and water efficiency label |
| Does it replace the other? | No. It does not establish a WELS star rating. | No. It does not replace required WaterMark certification. |
| Is the project automatically approved? | No. Installation requirements still need review. | No. The rating alone does not establish installation suitability. |
This comparison follows the government’s explanation of the two schemes. Keep a dated copy of the relevant evidence with each purchase line, rather than attaching one generic certificate to the whole bathroom package.
1. Identify the product and supply route
The official WELS product list includes taps used over fixed basins, sinks and laundry tubs, personal bathing showers, and water using lavatory equipment. It also lists exclusions: bath or spa only tap equipment, bidet taps and thermostatic taps are excluded from the WELS tap category. Second hand products and products imported for personal use are excluded from the WELS scheme.
Those exclusions do not establish an exemption from WaterMark installation requirements. Record whether you are importing for your own use or supplying products to others. An overseas checkout page and a familiar brand name cannot settle that distinction.
For a shower package, list the mixer, overhead shower, hand shower, hose and any flow controller separately. For a toilet, list the pan, cistern and flushing arrangement. A package name such as “complete bathroom set” is too broad for a reliable approval review.

2. Verify the WaterMark licence for the proposed fixture
WaterMark certification is required for plumbing products within the scheme’s scope. For regulated plumbing products intended for connection to reticulated water, valid WaterMark certification is a prerequisite for WELS registration. The WELS regulator’s WaterMark guidance also explains that installation is governed through state and territory plumbing requirements.
Ask for the WaterMark licence number, licence holder, product description and covered model details. Compare those details with the current listing in the ABCB WaterMark portal. If the model cannot be located, resolve that gap with the supplier and certifying body before approval.
A practical review has three outcomes: verified, awaiting clarification, or unsuitable for the proposed order. Keep “awaiting clarification” products out of the approved schedule. A photograph of a logo without a traceable licence is insufficient evidence for a purchasing decision.
Before buying imported tapware, send the listing and installation instructions to your licensed plumber. Ask whether the supplied configuration is covered and appropriate for the planned connection. Review substitutes again, even when the finish and appearance match the original selection.
3. Check the WELS registration and water efficiency label
Use the WELS product register to check the exact product offered. Look for the registered brand, model, status, star rating and stated water consumption. A search result for a similar product is a lead to investigate, rather than approval of the item in your quotation.
According to the official WELS display requirements, regulated products offered for supply need current registration and appropriate labelling. Online advertising can use the complete label with the registered model, or the specified registration number and water efficiency text advice. A standalone star arch is not a substitute for the required information.
Save the register entry alongside the quotation. If the listing, packaging and invoice use different model names, obtain a written explanation and corrected documents before shipment. Do not accept a screenshot that crops out the model identity or registration information.

4. Match the exact model, brand and components
The WELS plumbing application guidance requires model and brand details to match the registered product. Its examples distinguish product variants and configurations, including S trap and P trap lavatory equipment and combination showers. Similar appearance is not proof that two versions share the same registration.
Build a short reconciliation table before ordering:
| Order record | Document to compare | Action if different |
|---|---|---|
| Brand and full model identifier | Register entry, licence details and packaging | Request the correct entry and a revised quotation |
| Finish and supplied configuration | Specification sheet and covered variants | Confirm coverage rather than assuming it |
| Shower outlets and flow controller | Registered configuration and installation instructions | Resolve substitutions before approval |
| Toilet pan, cistern and trap arrangement | Registered equipment details and drawings | Confirm the combination and rough in requirements |
Keep this table with the purchase order. Add a rule that no model, cartridge, flow controller or fixture combination may be substituted without a new document review. This makes approval useful to the receiving team as well as the buyer.
5. Compare water use with installation needs
Read the consumption figure as well as the stars. The WELS label guide explains the relevant units: taps and showers use litres per minute, while toilet labels identify flush consumption. For dual flush toilets, check the full, reduced and average flush information rather than comparing a single unexplained number.
Water efficiency is one input to selection. Ask for the manufacturer’s operating pressure range, hot water requirements, connection dimensions and maintenance instructions. Have the installer check those against the site. A published shower head flow rate does not establish how a particular hot water system and shower arrangement will perform together.
For toilets, compare the outlet configuration, set out, cistern arrangement and service access before focusing on appearance. Our guide to types of Australian toilets can help you shortlist layouts; the model specific register entries and drawings should then support the procurement decision.

For a multiroom project, test the proposed sample arrangement before approving the whole schedule. Record the model and components used in that review. A later substitution should trigger another check, rather than inherit the sample’s approval automatically.
Choosing where the basin tap should be mounted? Compare wall mounted versus deck mounted taps for basin fit, rough in planning and service access before approving the fixture layout.
6. Check the project location and lead free transition
Write the state or territory, building use and expected installation date on the fixture schedule. Give those details to the installer and confirm any project specific water efficiency, accessibility and plumbing requirements. Avoid treating a national product registration as the final answer to every local installation question.
Lead Free WaterMark dates need particular care. The QBCC’s current lead free plumbing notice states that the supplier and installer compliance date was extended to 1 May 2028, while manufacturers still needed to comply by 1 May 2026. These are different milestones. Old summaries using one date for every participant can mislead buyers.
For a Queensland project, the same notice explains that non conforming building product duties extend across the chain of responsibility, including suppliers and installers. Check the current notice, applicable product scope and supporting documentation before placing or accepting the order. For another jurisdiction, verify the current position with its plumbing regulator.
Ask the supplier to identify which supplied components are covered by the lead free documentation, and have the installer review the evidence. Avoid accepting “lead free” as an unsupported marketing description or assuming that every component in a matching range has the same documented status.
7. Set purchase and delivery checkpoints
When importing tapware into Australia for supply, settle responsibilities before paying the deposit. The WELS industry guidance places registration responsibilities across the supply chain, including manufacturers, importers, wholesalers, retailers and building developers. Put the responsible party and document delivery date in the order record.
A useful bathroom procurement checklist follows the order through three stages:
- Before deposit: approve exact models, quantities, finish, current registration evidence, covered configuration and the installer’s review.
- Before shipment: reconcile packaging and invoice identifiers with the approved schedule; obtain final documents and confirm that no substitutions have been made.
- At delivery: inspect model markings, supplied parts and damage; isolate discrepancies and resolve them before installation.

Agree on replacement parts and service access as part of selection. For a concealed mixer, ask how the cartridge can be accessed and which replacement reference should be retained. For a toilet, record the flushing mechanism and seat references. These details help the maintenance team order the intended part later.
Compare supplier proposals using the same schedule. Include freight, document preparation, inspection, local installation work and replacement arrangements in the commercial review. A low unit price is difficult to assess when another proposal includes a different configuration or service commitment.
The most useful WaterMark vs WELS comparison ends with an approved product record, not a collection of logos. Keep the certificate, registration entry, specification, installer review and delivery reconciliation together so that each person can see what was actually selected.

Planning a bathroom package? Start with the room layout and intended fixture configuration. Review shower faucet set options and the bathroom showroom range, then send George your project details. Include the installation location, proposed models, quantities and the documents your project team needs. Confirm certification and registration for the exact supplied items before approval.
FAQs about WaterMark vs WELS
What is the difference between WaterMark and WELS?
WaterMark addresses plumbing product conformity and fitness for purpose. WELS addresses water efficiency registration and labelling. Many bathroom fixtures require checks under both schemes; neither replaces the other.
Does every bathroom tap need WELS registration?
No. The WELS tap category includes equipment used over fixed basins, sinks and laundry tubs, but excludes bath or spa only taps, bidet taps and thermostatic taps. Check the exact category and supply route separately from WaterMark installation requirements.
Can I import a tap for personal use without WELS registration?
The WELS scheme excludes products imported for personal use. That exclusion does not remove applicable WaterMark or local plumbing installation requirements. Have the exact product and documentation reviewed before buying.
Is a WELS star rating enough to approve an imported shower?
No. Check the current registration for the supplied shower configuration, applicable WaterMark certification and installation requirements. A rating for a similar model does not approve a different handset or component combination.
Can two finishes or toilet trap versions use the same registration?
Do not assume they can. Confirm that the exact variant is covered. The WELS plumbing guidance distinguishes model and configuration details, including S trap and P trap lavatory equipment. Match the order to the appropriate registration evidence.
What lead free date should Queensland buyers check?
As checked on 14 October 2026, QBCC states a 1 May 2028 compliance date for suppliers and installers, while manufacturers still needed to comply by 1 May 2026. Verify the current notice, product scope and documentation for the proposed order.
What should I request before paying a bathroom fittings deposit?
Request exact model and component details, applicable WaterMark licence information, WELS registration and label information, installation instructions and written confirmation of any proposed substitutions. Give the documents and project location to your installer before approving the schedule.