For STC vs OITC windows, start with the noise source and compare evidence for the complete window. OITC is generally more useful for outdoor transportation noise; STC remains a useful comparison measure for speech-related sound. Neither rating, by itself, promises the sound level inside your finished room.
A buyer can receive an impressive number without knowing whether it applies to the glass, a fixed window, or the opening sash actually being quoted. These seven checks help turn a noise complaint into a specification that suppliers can price and your project team can review. For the wider choice of materials and opening styles, use our window selection and project quotation guide.
1. Describe the noise before choosing a window
Write down which rooms are affected, the elevation facing the source and when the disturbance occurs. Distinguish passing vehicles, aircraft, conversation and bass-heavy music. A short description such as “front bedroom, road-facing, trucks before dawn, windows normally closed” gives a supplier a more useful starting point than “the highest soundproof rating.”
For a difficult site, ask an acoustic consultant to establish the relevant outdoor noise and indoor objective. Keep existing measurements with their method and conditions. A phone recording can help explain the concern; it should not be presented as a laboratory window test.

2. STC vs OITC windows: compare the same rating
STC means Sound Transmission Class. OITC means Outdoor-Indoor Transmission Class. Cardinal Glass’s OITC glossary explains that STC covers 125–4000 Hz, while OITC covers 80–4000 Hz and includes lower-frequency exterior sound. A higher value indicates better performance within the same rating system.
| Comparison | STC | OITC |
|---|---|---|
| Main buying use | Compare speech-related sound insulation | Compare outdoor transportation noise insulation |
| Frequency range | 125–4000 Hz | 80–4000 Hz |
| Ask the supplier for | The STC result and matching assembly | The OITC result and matching assembly |
| Do not assume | The number is the room’s decibel reduction | Every road or aircraft spectrum matches the reference |
ASTM E1332 uses a transportation reference spectrum, and warns that equal single-number ratings can transmit different frequency balances. Where rumble or another specific sound dominates, request the transmission-loss data by frequency and have the consultant review it. Do not convert an STC number into OITC with a universal subtraction.
Before requesting prices: agree which rating the project specification requires and attach that requirement to every enquiry. Ask each supplier to state whether the result is measured, calculated or drawn from another configuration.
3. Match the acoustic report to the complete window
Check the report against the order line: manufacturer and system, frame, sash arrangement, overall size, glazing makeup, seals, locking hardware and tested condition. If the proposed assembly differs, ask the supplier and specifier to explain whether the submitted evidence applies. A rating for a small fixed specimen is not sufficient identification of a large sliding combination.
ASTM E1425 addresses acoustic testing of windows and related systems, including applicable operating force, latching force and air leakage checks. These details matter when reviewing an operable window rather than a sealed piece of glass.
Keep the report number and date beside the quoted configuration. The Andersen acoustic performance document is one example of a manufacturer publishing product-specific STC and OITC records; it is not evidence for a George product.

4. Compare the glass package rather than pane count
Triple pane windows are not automatically the quieter choice. In its sound abatement guide, Andersen explains that glass thickness, spacing, mismatched pane thicknesses and laminated glass can affect sound performance, and that adding a third pane does not necessarily deliver a large acoustic improvement. Compare the actual tested alternatives.
Request an itemised acoustic glass description: pane thicknesses, cavity widths, laminated glass and interlayer where applicable, coating and total insulated glass unit thickness. Ask whether that package fits the proposed frame and whether the report names the same makeup. Avoid paying for a generic “acoustic upgrade” with no corresponding specification.

Remember to check our aluminum window condensation checklist when noise-control glazing is part of a cold-room replacement. Moisture diagnosis and acoustic selection answer different questions; keep both in the project brief.
5. Review installation, ventilation and other sound paths
A complete-window laboratory result does not settle the performance of its connection to the wall. ASTM E1425 explicitly excludes transmission through openings between the assembly and adjacent construction. Record who designs and installs the perimeter joint, and how the agreed detail will be inspected.
Ask the site team to consider adjacent doors, wall construction, vents and other potential paths before assigning the full problem to the glass. Keep required ventilation, drainage and safe opening functions in the design. Do not block a vent or drainage opening merely to make a room seem quieter.
Remember to check our window air leakage buying checklist to compare reported leakage evidence and installation responsibilities. An air leakage value is not an acoustic rating, but both records help identify what has actually been assessed.

6. Keep energy, safety and project requirements separate
Place acoustic performance in its own column of the window schedule, beside the project’s energy, safety glazing, wind, water, ventilation and opening requirements. Have the designer confirm the applicable rules for the actual location and use. Neither STC nor OITC is a universal approval certificate, and this guide does not prescribe a legal minimum for every country or state.
If a glass package changes during pricing, request the updated supporting records before accepting it. Do not assume the original energy rating, dimensions or local approval still describe the revised order. A supplier’s alternative should show each changed item clearly.
7. Send a quote brief that suppliers can answer
Use the same information for every bidder. That makes differences in scope visible before a deposit or production release.
- Project: country, state or region, building use, affected rooms and elevations.
- Openings: drawings, preliminary dimensions, quantities and required operating styles.
- Noise: source, timing, existing conditions and any consultant’s acoustic specification.
- Evidence: required STC/OITC records and frequency-band data where specified.
- Window package: frame, glass makeup, finish, hardware and accessories.
- Other criteria: project energy, safety, structural and ventilation requirements.
- Delivery and work: destination, supply or installation scope, perimeter detail responsibility and documentation required before production.
Ask the response to distinguish included work, exclusions and unresolved requirements. For casement windows, picture windows and sliding windows, compare the proposed configuration rather than treating an opening style as a guaranteed noise ranking.

Start your enquiry with George: share the opening schedule, project location and acoustic brief so the proposed window package and available supporting documents can be reviewed together. Final acceptance should use the exact products’ current documents and the project team’s requirements.
FAQs about STC vs OITC windows
Is OITC better than STC for traffic noise?
OITC is usually the more relevant starting point for road, rail and aircraft noise because its reference spectrum includes lower frequencies. Ask for both ratings and review frequency-band data when the actual noise differs from that reference.
Can I convert an STC rating into an OITC rating?
Do not use a fixed subtraction to convert a quotation. Ask the supplier for the separately calculated OITC result for the same tested window assembly.
Does an STC rating tell me how many decibels quieter my bedroom will be?
No. STC is a product comparison rating, not a promised reduction inside a particular room. The source, installation and other sound paths affect the installed outcome.
Are triple pane windows always quieter than double pane windows?
No. Pane count alone does not establish acoustic performance. Compare the tested complete assemblies, including glass thicknesses, cavities, seals and any laminated interlayer.
Is a glass only acoustic report enough to order a complete window?
A glass report does not identify the complete frame, sash, seals and hardware being purchased. Request assembly evidence and have the specifier resolve any mismatch before ordering.
What should I send for a noise control window quote?
Send the project location, room and elevation, opening sizes and quantities, noise concern, required opening function, any acoustic specification, energy and safety requirements, and the installation scope. Ask the supplier to identify the proposed configuration and supporting documents.
Explore window options for your project
Choose an opening style to develop the quotation. Acoustic performance must be verified for the selected assembly.
Casement Windows
Picture Windows
Sliding Windows